IEC 332-3 PDF

There are some standards that should receive special mention: IEC , IEC -1, IEC , IEC and IEC IEC is a circuit integrity test. IEC Specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables. Find the most up-to-date version of GOST R IEC at Engineering

Author: Mejind Yot
Country: Rwanda
Language: English (Spanish)
Genre: Software
Published (Last): 5 April 2014
Pages: 120
PDF File Size: 17.3 Mb
ePub File Size: 20.77 Mb
ISBN: 192-1-12046-595-8
Downloads: 38237
Price: Free* [*Free Regsitration Required]
Uploader: Zurr

Please inform us formally before our production and confirm the design firstly based on our sample. In addition, a failure shall be recorded if burning extends downwards to appoint greater than mm from the lower edge of the top support. The test sample is comprise a number a test pieces of cable from the same length, each having a minimum length of 3,5 m.

We use tracking services to be able to analyse the contents of our website and regularly improve them. Do you have any MOQ limit for electrical cable order? ASTM D Standard test methods for density and specific gravity ice gravity of plastic by displacement ASTM D Standard test method for specific optical density of smoke generated by solid materials.

Protecting your personal data is an important issue for us.

Flame Retardant – IEC 332-3-Cat.A (Non Armour)

IEC cable suitable for direct burial not for application in power circuits installation in free air without UV-protection cable UV-resistant cable with EAC-approval cable conform to Low Voltage directive. Fire detection and fire alarm systems for buildings. We store and analyse the collected data in a pseudonymized form. The wire or cable shall pass the test in the distance between the lower edge on the top support and the onset of charring is greater than 50 mm.

BS Specifications for conductors in insulated cables cords. Yes, we could offer the sample for free charge but do not pay the cost of freight. Test on electric cables under fire conditions – Test for vertical flame spread of vertically-mounted bunched wires or cables. IEC This part of IEC specifies a method to test on a single vertical insulated wire or cable under the conditions and the requirements for compliance. Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings.

TOP Related Posts  ANALYSE DISCRIMINANTE SPSS PDF

IEC The test sample is comprise a number a test pieces of cable from the same length, each having a minimum length of 3,5 m.

IEC | IEC Webstore

The standard is subdivided in several parts that differ one from the other for the quantity of cable to be installed, the installation mode and the flame application time. Exhibition-Part of the Project. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems BS Specification 33-3 performance requirements for cables required to maintain circuit integrity under fire conditions BS Electric cables.

This part of IEC specifies a method of testing a small insulated wire under the fire conditions when the method specified in IEC is not suitable because some small conductors may melt during the application of the flame.

Flame Retardant – IEC 332-3 Cat A (w/ Armour)

Tracking and web tracking settings. Shenzhen Eic Cables Ieec Co. China engine core China tablet pc quad core China amd quad core phenom ii. The flame shall be applied continuously for the period of time corresponding to the diameter shown in the table.

Specification for performance requirements for cables required to maintain circuit integrity under fire conditions. What about the lead time? The ignition source is a gas burner fed with propane. Standard test methods for density and specific gravity relative gravity of plastic by displacement.

Standard test method for tensile properties of plastics. China tablet quad core China tablet pc quad core 3g.

Test for vertical flame spread of vertically-mounted bunched wires or cables – Category D -Installation In one layer front. Code of practice for system design, installation, commissioning and maintenance.

TOP Related Posts  DARK VENGEANCE SARA REINKE PDF

The flame shall be applied continuously for the period of time corresponding to the diameter uec in the table. Specification BS Methods of test for assessment of the fire integrity of electric cables.

Test on bunched wire or cables. They for example include the real name, address, telephone number and date of birth, but also all other data that can be traced to an identifiable person. Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications.

After burning the maximum extend of the charred portion of test sample should not have reached a height exceeding 2,5 m above the bottom edge of the burner, neither at the front nor the rear of the ladder. If the failure is recorded two more tests shall be carried out. In addition, a failure shall be recorded if burning extends downwards to appoint greater than mm from the lower edge of the top support. The test sample is comprise a number a test pieces of cable from the same length, each having a minimum length of 3,5 m.

Test on electric cables under fire conditions. Fire resistant cables – Performance requirements for cables required to maintain circuit integrity under fire conditions. This part of IEC specifies a method of testing a small insulated wire under the fire conditions when the method specified in IEC is not suitable because some small conductors may melt during the application of the flame.

Tests on electric and optical fiber cables under fire conditions – Part If the failure is recorded two more tests shall be carried out. Standard test method for specific optical density of smoke generated by solid materials. Fire detection and alarm systems for buildings.